Laboratory dryers, sterilizers – the 'SP' series
Standard equipment:
- Temperature range Tambient + 5°C ÷ 300°C
- Forced air circulation with a fan
- Innovative air flow system, which enables high temperature uniformity and stability
- Simple microprocessor controller with a LED display
- Timer or continuous operation
- PID temperature controller
- Visual and sound alarm in the event of failure
- LED indication:
- Operation of the heaters
- Operation of the fan
- Programme in operation
- Programme completed
- Programme stopped with STOP
- Temperature sensor error
- Display temperature resolution 0.1°C
- Temperature stability ± 0.1°C
- Adjustable exhaust system with a lever on the doors
- Double protection system against high temperatures
- when the temperature is 5°C above the set level, the operation of the heating elements is disabled
- mechanical over temperature shut off device
- The interiorcasing is made of stainless steel AISI 304
- The exterior is made of aluminized sheet, powder coated (RAL 7035)
- Two stainless steel wire shelves
- Interlock with the possibility of locking (keys added)
- RS – 232 communication port
- Programme for the temperature probe calibration
- Instructions for working with the electrical layout and the CE declaration of conformity
Type
|
Volume
|
Internal dimensions (WxHxL) mm
|
External dimensions (WxHxL) mm
|
Wattage
|
SP – 45
|
44 L
|
355 x 335 x 370
|
590 x 560 x 600
|
230V~50/60 Hz 1,25 kW
|
SP – 105
|
105 L
|
490 x 500 x 430
|
725 x 725 x 660
|
230V~50/60 Hz 1,65 kW
|
SP – 160
|
163 L
|
650 x 560 x 450
|
855 x 785 x 680
|
230V~50/60 Hz 2,25 kW
|
SP – 190
|
190 L
|
600 x 615 x 515
|
835 x 840 x 745
|
230V~50/60 Hz 2,25 kW
|
SP – 210
|
210 L
|
700 x 600 x 500
|
935 x 825 x 730
|
230V~50/60 Hz 2,25 kW
|
SP – 250
|
250 L
|
500 x 1000 x 500
|
735 x 1230 x 720
|
230V~50/60 Hz 3,3 kW
|
SP – 265
|
264 L
|
600 x 800 x 550
|
835 x 1025 x 780
|
230V~50/60 Hz 3,25 kW
|
SP – 440
|
440 L
|
1000 x 800 x 550
|
1235 x 1025 x 735
|
3x400V~50/60 Hz 3,7 kW
|
SP – 210
|
210 L
|
700 x 600 x 500
|
935 x 825 x 730
|
230V~50/60 Hz 2,25 kW
|
SP – 910
|
910 L
|
1000 x 1300 x 700
|
1280 x 1975 x 875
|
3x400V~50/60 Hz 9,5 kW
|
SP – 1300
|
1288 L
|
1060 x 1430 x 850
|
1340 x 2100 x 990
|
3x400V~50/60 Hz 10,5 kW
|
Laboratory dryers, sterilizers –'SP' series and the 'C' series controller
Standard equipment:
- Temperature range Tambient + 5°C ÷ 300°C
- Forced air circulation with a fan
- Innovative air flow system, which enables high temperature uniformity and stability
- Microprocessor controller with an LCD display – fully programmable
- 10 automatic programmes
- Up to 10 steps in each programme
- Fan speed adjustment
- Start-up (at a specified time and day)
- … other advanced functions
- Timer or continuous operation
- PID temperature controller
- Visual and sound alarm in the event of failure
- LED indication:
- Operation of the heaters
- Operation of the fan
- Programme in operation
- Programme completed
- Programme stopped with STOP
- Temperature sensor error
- Display and temperature setting resolution 0.1°C
- Temperature stability ±0.1°C
- An adjustable exhaust system with a lever on the doors
- Double protection system against high temperatures
- when the temperature is 5°C above the set level, the operation of the heating elements is disabled
- mechanical over temperature shut off device
- The interior casing is made of stainless steel AISI 304
- The exterior is made of aluminized sheet, powder coated RAL 7035
- Two stainless steel wire shelves
- RS – 232 communication port
- Interlock with the possibility of locking (keys added)
- Programme for the temperature probe calibration
- Instructions for working with the electrical layout and the CE declaration of conformity
Type
|
Volume
|
Internal dimensions (WxHxL) mm
|
External dimensions (WxHxL) mm
|
Wattage
|
SP – 45 C
|
44 L
|
355 x 335 x 370
|
590 x 560 x 600
|
230V~50/60 Hz 1,25 kW
|
SP – 105 C
|
105 L
|
490 x 500 x 430
|
725 x 725 x 660
|
230V~50/60 Hz 1,65 kW
|
SP – 160 C
|
163 L
|
650 x 560 x 450
|
855 x 785 x 680
|
230V~50/60 Hz 2,25 kW
|
SP – 190 C
|
190 L
|
600 x 615 x 515
|
835 x 840 x 745
|
230V~50/60 Hz 2,25 kW
|
SP – 210 C
|
210 L
|
700 x 600 x 500
|
935 x 825 x 730
|
230V~50/60 Hz 2,25 kW
|
SP – 250 C
|
250 L
|
500 x 1000 x 500
|
735 x 1230 x 720
|
230V~50/60 Hz 3,3 kW
|
SP – 265 C
|
264 L
|
600 x 800 x 550
|
835 x 1025 x 780
|
230V~50/60 Hz 3,25 kW
|
SP – 440 C
|
440 L
|
1000 x 800 x 550
|
1235 x 1025 x 735
|
3x400V~50/60 Hz 3,7 kW
|
SP – 910 C
|
910 L
|
1000 x 1300 x 700
|
1280 x 1975 x 875
|
3x400V~50/60 Hz 9,5 kW
|
SP – 1300 C
|
1288 L
|
1060 x 1430 x 850
|
1340 x 2100 x 990
|
3x400V~50/60 Hz 10,5 kW
|
Laboratory dryers, sterilizers - 'S' series with natural air circulation
Standard equipment:
- Temperature range Tambient + 5°C ÷ 300°C
- Natural circulation without the fan
- Innovative air flow system, which enables high temperature uniformity and stability
- Simple microprocessor controller with a LED display
- Timer or continuous operation
- PID temperature controller
- Visual and sound alarm in the event of failure
- LED indication:
- Operation of the heaters
- Programme in operation
- Programme completed
- Programme stopped with STOP
- Temperature sensor error
- Display temperature resolution 0.1°C
- Temperature stability ±0.1°C
- An adjustable exhaust system with a lever on the doors
- Double protection system against high temperatures
- when the temperature is 5°C above the set level, the operation of the heating elements is disabled
- mechanical over temperature shut off device
- The interior casing is made of stainless steel AISI 304
- The exterior is made of aluminized sheet, powder coated (RAL 7035)
- Two stainless steel wire shelves
- RS – 232 communication port
- Interlock with the possibility of locking (keys added)
- Programme for the temperature probe calibration
- Instructions for working with the electrical layout and the CE declaration of conformity
Type
|
Volume
|
Internal dimensions (WxHxL) mm
|
External dimensions (WxHxL) mm
|
Wattage
|
S – 50
|
50 L
|
355 x 335 x 415
|
590 x 560 x 600
|
230V~50/60 Hz 1,2 kW
|
S – 115
|
116 L
|
490 x 500 x 475
|
725 x 725 x 660
|
230V~50/60 Hz 1,6 kW
|
S – 205
|
206 L
|
600 x 615 x 560
|
835 x 840 x 745
|
230V~50/60 Hz 2,2 kW
|
S – 285
|
285 L
|
600 x 800 x 595
|
835 x 1025 x 780
|
230V~50/60 Hz 3,25 kW
|
S – 475
|
476 L
|
1000 x 800 x 595
|
1235 x 1025 x 735
|
3x400V~50/60 Hz 3,7 kW
|
Laboratory dryers, sterilizers – 'S' series with natural air circulation and a 'C' series controller
Standard equipment:
- Temperature range Tambient + 5°C ÷ 300°C
- Natural air circulation without the fan
- Innovative air flow system, which enables high temperature uniformity and stability
- Microprocessor controller with an LCD display – fully programmable
- 10 automatic programmes
- Up to 10 steps in each programme
- Start-up (at a specified time and day)
- … other advanced functions
- Timer or continuous operation
- PID temperature controller
- Visual and sound alarm in the event of failure
- LED indication:
- Operation of the heaters
- Programme in operation
- Programme completed
- Programme stopped with STOP
- Temperature sensor error
- Display and temperature setting resolution 0.1°C
- Temperature stability ±0.1°C
- An adjustable exhaust system with a lever on the doors
- Double protection system against high temperatures
- when the temperature is 5°C above the set level, the operation of the heating elements is disabled
- mechanical over temperature shut off device
- The interior casing is made of stainless steel AISI 304
- The exterior is made of aluminized sheet, powder coated (RAL 7035)
- Two stainless steel wire shelves
- RS – 232 communication port
- Interlock with the possibility of locking (keys added)
- Programme for the temperature probe calibration
- Instructions for working with the electrical layout and the CE declaration of conformity
Type
|
Volume
|
Internal dimensions (WxHxL) mm
|
External dimensions (WxHxL) mm
|
Wattage
|
S – 50 C
|
50 L
|
355 x 335 x 415
|
590 x 560 x 600
|
230V~50/60 Hz 1,2 kW
|
S – 115 C
|
116 L
|
490 x 500 x 475
|
725 x 725 x 660
|
230V~50/60 Hz 1,6 kW
|
S – 205 C
|
206 L
|
600 x 615 x 560
|
835 x 840 x 745
|
230V~50/60 Hz 2,2 kW
|
S – 285 C
|
285 L
|
600 x 800 x 595
|
835 x 1025 x 780
|
230V~50/60 Hz 3,25 kW
|
S – 475 C
|
476 L
|
1000 x 800 x 595
|
1235 x 1025 x 735
|
3x400V~50/60 Hz 3,7 kW
|
Simple dryers, sterilizers - 'EASY' series dry
Standard equipment:
- Temperature range Tambient + 5°C ÷ 300°C
- Forced air circulation with a fan
- Simple digital controller with LED display
- PID temperature regulator
- Visual and sound alarm in the event of failure
- Timer function – one stage
- Display temperature resolution 0.1°C
- Adjustable exhaust
- The interior casing is made of stainless steel (AISI 304)
- The exterior is made of aluminized sheet, powder coated (RAL 7035)
- Two stainless steel wire shelves
- RS – 232 communication port
- Interlock with the possibility of locking (keys added)
- Programme for the temperature probe calibration
- Instructions for working with the electrical layout and the CE declaration of conformity
Functionality:
- Sterilization with hot air
- Material drying
- Heating medium or industrial masses
Advantages:
- Very simple to use
- Perfect balance between the exterior dimensions and used volume
- Inner rounded edges of the chamber enable a simple and quality cleaning
- Light weight of the equipment
- Easily adjustable shelf height
Type
|
Volume
|
Internal dimensions (WxHxL) mm
|
External dimensions (WxHxL) mm
|
Wattage
|
SP - 25 EASY
|
25 L
|
250 x 350 x 300
|
360 x 470 x 520
|
230V~50/60Hz 0,9 kW
|
SP - 55 EASY
|
55 L
|
400 x 400 x 350
|
510 x 520 x 570
|
230V~50/60Hz 0,9 kW
|
SP - 120 EASY
|
120 L
|
600 x 500 x 400
|
710 x 620 x 620
|
230V~50/60Hz 1,6 kW
|
SP - 240 EASY
|
240 L
|
600 x 800 x 500
|
710 x 920 x 720
|
230V~50/60Hz 1,6 kW
|
Additional equipment:
- Calibration with a report (10 points 3 temperatures)
- Calibration with a report (1 point 1 temperature)
- An additional shelf for all models
- Ventilation unit for additional extraction
- Special extra features depending on the client's needs
Laboratory varnish dryers with special protection systems
The LSP Dryers are designed to assist the industrial processes of varnish drying using the processes of COIL COATING, HOT AIR CYCLE, etc. We recommend them to paint and varnish manufacturers for material testing and optimum setting of working parameters with larger dryers. All dryers have a built-in programme for rapid temperature probe calibration.
Standard equipment:
- Temperature range Tambient + 5°C ÷ 300°C
- Forced air circulation with a fan
- Forced circulation of fresh air – safety function, when the flow is suspended, the operation of heaters is shut down
- Fresh air flow control – safety function, when the flow is suspended, the operation of the heaters is shut down
- Flow control of inner air
- Microprocessor controller with an LCD display – fully programmable
- 10 automatic programmes
- Up to 10 steps in each programme
- Start-up (at a specified time and day)
- … other advanced functions
- Timer or continuous operation
- PID temperature controller
- Visual and sound alarm in the event of failure
- LED indication:
- Operation of the heaters
- Operation of the fan
- Programme in operation
- Programme completed
- Programme stopped by STOP
- Error
- Display and temperature setting resolution 0.1°C
- Temperature stability ±0.1°C
- Double protection system against the high temperatures
- when the temperature is 5°C above the regulated level, the operation of the heaters is shut down,
- mechanical safety thermostat
- The interior casing is made of stainless steel AISI 304
- The exterior is made of aluminized sheet, powder coated (RAL 7035)
- Two stainless steel wire shelves
- RS – 232 communication port
- Interlock with the possibility of locking (keys added)
- Programme for the temperature probe calibration
Instructions for working with the electrical layout and the CE declaration of conformity
Type
|
Internal dimensions (WxHxL) mm
|
External dimensions (WxHxL) mm
|
Wattage
|
LSP-45 C
|
350 x 350 x 350
|
940 x 845 x 960
|
230V~50/60Hz 1,6 kW
|
LSP-105 C
|
490 x 500 x 430
|
870 x 785 x 615
|
230V~50/60Hz 3,1 kW
|
LSP-190 C
|
600x615x515
|
980x900x700
|
3x400V~50/60Hz 4,6 kW
|
LSP-210 C
|
580 x 600 x 600
|
1000 x 1550 x 1100
|
3x400V~50/60Hz 12,0 kW
|
LSP-215 C
|
|
|
|
LSP-252 C
|
|
|
|
High Temperature Chambers - Dryers
Standard equipment:
- Temperature range Tambient + 5°C - 500°C (600°C)
- Forced air circulation with a fan
- Innovative air flow system, which enables high temperature uniformity and stability
- Microprocessor controller with an LCD display – fully programmable
- 10 automatic programmes
- Up to 10 steps in each programme
- Fan speed adjustment
- Start-up (at a specified time and day)
- Other advanced functions
- Timer or continuous operation
- PID temperature controller
- Visual and sound alarm in the event of failure
- Display and temperature setting resolution: 1°C
- Temperature stability ± 1°C
- Adjustable exhaust system
- Double protection system against the elevated temperature
- when the temperature is 5°C above the regulated, the operation of the heaters elements is shut down,
- mechanical safety thermostat
- The exterior is made of aluminized sheet, powder coated (RAL 7035)
- Two stainless steel wire shelves
- RS – 232 communication port
- Programme for the temperature probe calibration
- Strong construction
- Ceramic insulation with an air pocket to prevent the heating of the exterior casing
The instructions for working with the electrical layout and the CE declaration of conformity
Type
|
Internal dimensions (WxHxL) mm
|
External dimensions (WxHxL) mm
|
Wattage
|
SP – 60 C FIRE
|
400 x 400 x 390
|
950 x 670 x 780
|
3x400V~50/60Hz 3,2 kW
|
SP – 60 C FIRE (230V 1N)
|
400 x 400 x 390
|
950 x 670 x 780
|
230V~50/60Hz 2,8 kW
|
SP – 190 C FIRE
|
600 x 600 x 530
|
950 x 845 x 960
|
3x400V~50/60Hz 9,2 kW
|
SP – 320 C FIRE
|
825 x 525 x 820
|
1540 x 1620 x 1340
|
3x400V~50/60Hz 20 kW
|
Optional additional equipment
- Calibration with a report (10 points, 3 temperatures)
- Additional wire shelf
- Additional shelf made of perforated sheet
- Access port with plugs (S 40mm , S 50mm , S 90mm)
- The interior is constructed with the AISI 316 material
- Observation glass on the doors and a light in the chamber
- Printer for recording the procedure
- Software equipment for monitoring and recording the measured values on a PC
|